【Screw Press】Mechanical Failure

2024-08-06 Newwish QI

1. The system prompts that the set mold life has expired, please replace the mold


Cause: The set mold life has expired


Solution: Replace the mold





2. The slider return displacement deviation is more than 10mm


Cause:


1) The fixed part of the stroke encoder is loose


2) The coupling of the stroke encoder is loose or broken


3) The synchronous belt is loose


Solution: Tighten or replace the loose parts






3. The slider can move up and down, but the real-time stroke display value of the slider on the touch screen remains unchanged. Problem with installation of travel encoder


Cause:


Problem with installation of travel encoder


Abnormal 24V DC power supply voltage


Fault in PLC, travel encoder or counting circuit


Solution:


1) Check the installation of travel encoder and take corresponding measures


2) Please contact our after-sales service department


3) Slowly turn the travel encoder and observe whether the indicator light of the I0.0 port of PLC flashes. If it flashes, the PLC fails; if it does not flash, the travel encoder or counting circuit fails






4. System prompt: Slider overtravel, please reduce the set impact stroke appropriately


Cause:


1) Slider overtravel


2) Limit sensor damaged


Solution:


1) Reduce the set impact stroke appropriately


2) Replace the limit sensor






5. The slider cannot move when moving up and down


Cause:


1) Flywheel brake is not lifted


2) Motor bearing is stuck


3) Other mechanical stuck, such as oil seal ring and screw stuck, copper nut and screw stuck


Solution:


1) Manually check the brake action


2) After removing the pinion, manually turn or jog. If the motor shaft still cannot turn, the motor bearing needs to be replaced


3) Other mechanical stuck, remove the corresponding mechanical part and eliminate the cause of the stuck






6. The slider is weak and the sound is loud and mixed


Cause:


1) Insufficient lubrication of the main screw and nut


2) Insufficient lubrication of thin oil


Solution:


1) Clean the oil stains and replace with new grease


2) Clean the oil station and replace with new oil






7. The slider suddenly hits the top


Cause:


1) During the return stroke, the slider fork is disengaged from the travel encoder device, resulting in failure of the travel monitoring, and the slider keeps moving upward


2) The travel encoder coupling breaks during the return stroke


Solution:


1) Add a fixing plate to press the fork to prevent disengagement


2) Replace the coupling






8. The slider slips


Cause: Failure of the brake pad or brake spring


Solution: Replace the brake pad or brake spring






9. The fuselage shakes significantly


Cause: The anchor bolts and wedges are loose


Solution: Open the foundation cover, re-tighten the screws and wedges, and spot weld if necessary






10. 2310 Overcurrent alarm


Cause: The top encoder is not installed properly


Solution: Check the installation of the top encoder






11. 7381 Top encoder feedback fault


Cause: Top encoder failure, improper installation or top encoder shaft breakage


Solution: Check the top encoder and top encoder shaft, and re-adjust and install the top encoder






12. 90.12 The top encoder does not return to zero


Cause: top encoder fault


Solution: Replace the top encoder






13. 7310 Overspeed alarm


Cause: top encoder fault


Solution: Check the installation of the top encoder






14. 3385 Automatic phase identification error


Cause: The screws fixing the top encoder are loose and the angle is deviated


Solution: Tighten the screws and automatically find the phase again